| Sign In | Join Free | My chinabagsnet.com | 
              
  | 
      
Place of Origin : China
Brand Name : JH
Certification : CE
Model Number : S-75-15
Protection : Over load protection, short circuit protection
MOQ : 1pc
Packaging Details : 1pc/box
Payment Terms : T/T, Paypal, Western union
Supply Ability : 30000pcs per month
Output Voltage : 15V
Output Frequency : 47~63Hz
Output Current : 5A
Output Power : 51 - 100W
Output Type : Single
Input Voltage : 110V/220V
Single Output switching power supply 75W 15V 5A Transformer AC to DC Converter
 
 
 
Features:
1. Reliable quality and good price
2. High efficiency and low working temperature
3. Built-in EMI filter
4. 100% full-load burn-in test
5. Protection: Over load protection, short circuit protection
 
 
Specification:
Model number  | S-75-5  | S-75-12  | S-75-15  | S-75-24  | 
DC Output Voltage  | 5V  | 12V  | 15V  | 24V  | 
Output Voltage Error  | ± 2%  | ± 2%  | ± 1%  | ± 1%  | 
Rated Output Current  | 15A  | 6.3A  | 5A  | 3.2A  | 
Output Current Range  | 0-15A  | 0-6.3A  | 0-5A  | 0-3.2A  | 
Ripple and Noise  | 100mVp-p  | 75mVp-p  | 75mVp-p  | 75mVp-p  | 
Inlet Stability  | ± 0.5%  | ± 0.5%  | ± 0.5%  | ± 0.5%  | 
Load Stability  | ± 1%  | ± 0.5%  | ± 0.5%  | ± 0.5%  | 
DC Output Power  | 75W  | 75W  | 75W  | 76.8W  | 
Efficiency  | 74%  | 81%  | 82%  | 84%  | 
Adjustable Range for DC Voltage  | +10%, -5%  | ± 10%  | ± 10%  | ± 10%  | 
AC Input Voltage Range  | 85~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDC  | |||
Input Current  | 1.6A/115V 0.8A/230V  | |||
AC Inrush Current  | Cold-Start Current: 18A/115V, 36A/230V  | |||
Leakage Current  | <0.5mA/240VAC  | |||
Overload Protection  | 105%~150% Type: Cut Output, Reset: Auto Recovery  | |||
Over Voltage Protection  | ..........  | |||
Temperature Coefficient  | ± 0.03% /°C (0~50°C)  | |||
Start, Rise, Hold time  | 200ms, 100ms, 30ms  | |||
Vibration  | 10~500Hz, 2G 10min, /1 cycle, a total of 60 minutes, Each axes  | |||
Withstand Voltage  | Input and Output Interval: 1.5KVAC, Input and Enclosure: 1.5KVAC, Output and Enclosure: 0.5KVAC  | |||
Isolation Resistance  | Input and Output Interval: Input and Enclosure, Output and Enclosure: 500VDC/100M Ohms  | |||
Working Temperature and Humidity  | -10°C~+60°C (Refer to Output Derating Curve), 20%~90%RH  | |||
Dimension  | 157*97*38 mm  | |||
Weight  | 0.6kg  | |||
Safety Standards  | Meet UL 1012 requirement (Not apply for the mark)  | |||
EMC Standards  | .........  | |||
 
1. The testing condition for the parameter above is: 230VAC input, rated load, 25°C 70%RH, Humidity .      
2. Error, include the setting error, line stability and load stability.      
3. Wave test: adopting "A12" twisted pair wire for 20MHz, and 0.1uF-47uF capacitor short-circuit for interrupting .      
4. Inlet Voltage Stability test: when it is over load, the lowest voltage of inlet is representative to the highest voltage .      
5. Load stability test: the load is from 0% to 100% . 
 
 
 
Dimension      unit:mm
 
 
 
| 
                                             | 
                
                        Single Output switching power supply 75W 15V 5A Transformer AC to DC Converter Images |